Metaglas MetaClamp 2 in. tri-clamp sight glass, reverse side
RTK-101142-001

Rayotek 2" Tri-Clamp Sight Glass, Borosilicate & 2205 Duplex

$449.95BACKORDERED
BACKORDERED. Ship date to be confirmed. You can order now and it ships as soon as it is in.

ABOUT THIS PART

A 2 inch tri clamp sight window, borosilicate fused directly to a 2205 duplex stainless ring. Rayotek part number 101142-001. $449.95 each, and most builds take two.

SPECIFICATIONS

Part numberRayotek 101142-001
TypeFused sight window, 2 in tri clamp
GlassBorosilicate, fused to the ring
Ring material2205 duplex stainless
Wetted materialsDuplex stainless and borosilicate
Connection2 in tri clamp
Max pressure300 psi, which is 20.7 bar
Min pressure-15 psi, which is -1.0 bar
Temperature range-40 F to 572 F, which is -40 C to 300 C
Source of ratings3P Certz report ECR-250902-R0, Appendix A
System design pressure250 psi, which is 17.2 bar, on an N.B. Oler hydrocarbon system
System exposure in service-14 to 250 psi, which is -1.0 to 17.2 bar, and -20 F to 110 F, which is -29 C to 43 C
Vacuum limitThis part is the limiting component on minimum pressure for the whole system, at -15 psi, which is -1.0 bar
Price$449.95 each
Typical quantityTwo per sight spool
Also needsOne 2 in gasket and one 2 in high pressure clamp per window, sold separately
Gasket between glass and ringNone. The glass is fused to the metal
InspectionInspect before every install. Any chip, crack or scratch means the window comes out of service
NeverModify, machine or re-face a sight window
CleaningSoft cloth and a solvent compatible with borosilicate and 2205. No abrasives, no metal tools on the glass
AvailabilityBuilt to order. Contact the shop for lead time
Alternative in stock2 in MetaClamp window, same price

Certified ratings

Part number Rayotek 101142-001
Connection 2 in tri clamp
Glass Borosilicate, fused to the ring
Wetted materials Duplex stainless and borosilicate
Maximum pressure 300 psi (20.7 bar)
Minimum pressure -15 psi (-1.0 bar)
Temperature -40 °F to 572 °F (-40 °C to 300 °C)
Source 3P Certz report ECR-250902-R0, Appendix A
Price $449.95 each, two per sight spool
Availability Built to order. Contact the shop for lead time

Those are the figures recorded against this exact part number in our own certification report, not a catalog claim. Three things follow from them.

  • 300 psi (20.7 bar) is the glass. 250 psi (17.2 bar) is the system. An N.B. Oler hydrocarbon system is designed to 250 psi (17.2 bar), and that is what the relief valve is set to. The lowest applicable limit always governs, so do not read 300 psi (20.7 bar) as permission to run a system to 300 psi.
  • -15 psi (-1.0 bar) is your vacuum limit for the whole assembly. ECR-250902-R0 names the 2 inch sight glass as the limiting component on minimum pressure. Everything else in the system goes deeper.
  • The glass is fused to the metal ring rather than clamped against a seal, so there is no gasket inside the window to creep, take a set or be attacked by solvent. You still need a gasket at the tri clamp joint itself.

Rayotek or MetaClamp

We stock both and fit them interchangeably, whichever is on the shelf. This one is built to order at the moment. Our 2 inch MetaClamp window is in stock at the same price if you need one today.

Rayotek, this page MetaClamp
Pressure 300 psi (20.7 bar) 230 psig (15.9 bar)
Temperature -40 °F to 572 °F (-40 °C to 300 °C) 536 °F (280 °C)
Minimum pressure -15 psi (-1.0 bar) Not published
Named by part number in ECR-250902-R0 Yes No
Price $449.95 $449.95

If you are matching existing windows on a system, match what you already have. If you are certifying or recertifying, confirm your choice with your own certifier.

What you also need

  • Two windows per sight spool, one in each 2 inch port
  • One 2 inch gasket per window, Viton or PTFE envelope
  • One 2 inch high pressure clamp per window
  • The spool itself, 4 inch or 6 inch, if you do not already have one

Fits our 4 inch and 6 inch sight glass spools, and any standard 2 inch tri clamp port. Nothing in the list above is included.

Handling

  • Inspect before every install. A chipped, cracked or scratched window comes out of service and does not go back in
  • Never modify, machine or re-face a sight window
  • Clean with a soft cloth and a solvent compatible with borosilicate and 2205. No abrasives, nothing metal on the glass face

Built to order, shipped from Bend, Oregon.

FITSFits the two 2 inch ports on N.B. Oler 4 inch and 6 inch sight glass spools, two windows per spool, and any standard 2 inch tri clamp port. Named in 3P Certz report ECR-250902-R0 as the sight glass on N.B. Oler hydrocarbon systems. Interchangeable with the 2 inch MetaClamp window. Each window needs its own 2 inch gasket and 2 inch high pressure clamp.

▦ IN YOUR MANUAL

This part appears in the operator manual that ships with your system. The QR code there links to this page.

◈ REFERENCE FOR THIS PART

Certifications and Compliance →
what a third party certification report covers and how the sight glass is listed in it

COMMON QUESTIONS

What pressure is it rated for?

300 psi, which is 20.7 bar, maximum, and -15 psi, which is -1.0 bar, minimum, from 3P Certz report ECR-250902-R0, Appendix A, against this exact part number.

What temperature range?

-40 F to 572 F, which is -40 C to 300 C. Same source.

Why do you quote 250 psi elsewhere?

Because 250 psi, which is 17.2 bar, is the design pressure of an N.B. Oler hydrocarbon system, and 300 psi, which is 20.7 bar, is the rating of the glass. Two different numbers about two different things. Your relief valve is set for the system, not the window. The lowest applicable limit always governs.

How many do I need?

Two per sight spool, one in each 2 inch port.

What else do I need to install it?

One 2 in gasket and one 2 in high pressure clamp per window. Neither is included.

Is there a gasket between the glass and the metal?

No. The glass is fused directly to the 2205 duplex ring, so there is no seal in there to creep or degrade. You still need a gasket at the tri clamp joint itself.

Rayotek or Metaglas, which should I buy?

We stock both and use them interchangeably. Both are borosilicate in duplex stainless at 2 inch tri clamp. The Rayotek is the one named in our current certification report and publishes a higher temperature, 572 F, which is 300 C, against 536 F, which is 280 C. If you are matching windows already on a system, match what is there.

Can I run vacuum on it?

Down to -15 psi, which is -1.0 bar. On an N.B. Oler system this part is the limiting component on minimum pressure, so it sets the vacuum limit for the whole assembly.

What do I do if it gets scratched or chipped?

Take it out of service and replace it. Do not run a damaged sight window and do not try to polish or re-face one.

How do I clean it?

Soft cloth and a solvent compatible with borosilicate and 2205 duplex. No abrasives and nothing metal on the glass face.

Is it in stock?

Not at the moment. It is built to order, so contact the shop for lead time. Our 2 inch MetaClamp window is in stock at the same price if you need one now.

What is it made of?

Borosilicate glass fused to a 2205 duplex stainless ring.